iio: fix pressure data output unit in hid-sensor-attributes
commit 36afb176d3c9580651d7f410ed7f000ec48b5137 upstream. According to IIO ABI definition, IIO_PRESSURE data output unit is kilopascal: http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio This patch fix output unit of HID pressure sensor IIO driver from pascal to kilopascal to follow IIO ABI definition. Signed-off-by: Kweh, Hock Leong <hock.leong.kweh@intel.com> Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
58ddc44333
commit
4b90e67c84
|
@ -56,8 +56,8 @@ static struct {
|
|||
{HID_USAGE_SENSOR_ALS, 0, 1, 0},
|
||||
{HID_USAGE_SENSOR_ALS, HID_USAGE_SENSOR_UNITS_LUX, 1, 0},
|
||||
|
||||
{HID_USAGE_SENSOR_PRESSURE, 0, 100000, 0},
|
||||
{HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 1, 0},
|
||||
{HID_USAGE_SENSOR_PRESSURE, 0, 100, 0},
|
||||
{HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 0, 1000},
|
||||
};
|
||||
|
||||
static int pow_10(unsigned power)
|
||||
|
|
Loading…
Reference in New Issue
Block a user