661 lines
17 KiB
C
661 lines
17 KiB
C
/*
|
|
* sec_fuelgauge.c
|
|
* Samsung Mobile Fuel Gauge Driver
|
|
*
|
|
* Copyright (C) 2012 Samsung Electronics
|
|
*
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*/
|
|
|
|
#define DEBUG
|
|
|
|
#include <linux/battery/sec_fuelgauge.h>
|
|
#include <linux/of_gpio.h>
|
|
|
|
static struct device_attribute sec_fg_attrs[] = {
|
|
SEC_FG_ATTR(reg),
|
|
SEC_FG_ATTR(data),
|
|
SEC_FG_ATTR(regs),
|
|
};
|
|
|
|
static enum power_supply_property sec_fuelgauge_props[] = {
|
|
POWER_SUPPLY_PROP_STATUS,
|
|
POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
|
POWER_SUPPLY_PROP_VOLTAGE_AVG,
|
|
POWER_SUPPLY_PROP_CURRENT_NOW,
|
|
POWER_SUPPLY_PROP_CURRENT_AVG,
|
|
POWER_SUPPLY_PROP_CHARGE_FULL,
|
|
POWER_SUPPLY_PROP_ENERGY_NOW,
|
|
POWER_SUPPLY_PROP_CAPACITY,
|
|
POWER_SUPPLY_PROP_TEMP,
|
|
POWER_SUPPLY_PROP_TEMP_AMBIENT,
|
|
};
|
|
|
|
/* capacity is 0.1% unit */
|
|
static void sec_fg_get_scaled_capacity(
|
|
struct sec_fuelgauge_info *fuelgauge,
|
|
union power_supply_propval *val)
|
|
{
|
|
val->intval = (val->intval < fuelgauge->pdata->capacity_min) ?
|
|
0 : ((val->intval - fuelgauge->pdata->capacity_min) * 1000 /
|
|
(fuelgauge->capacity_max - fuelgauge->pdata->capacity_min));
|
|
|
|
dev_dbg(&fuelgauge->client->dev,
|
|
"%s: scaled capacity (%d.%d)\n",
|
|
__func__, val->intval/10, val->intval%10);
|
|
}
|
|
|
|
/* capacity is integer */
|
|
static void sec_fg_get_atomic_capacity(
|
|
struct sec_fuelgauge_info *fuelgauge,
|
|
union power_supply_propval *val)
|
|
{
|
|
if (fuelgauge->pdata->capacity_calculation_type &
|
|
SEC_FUELGAUGE_CAPACITY_TYPE_ATOMIC) {
|
|
if (fuelgauge->capacity_old < val->intval)
|
|
val->intval = fuelgauge->capacity_old + 1;
|
|
else if (fuelgauge->capacity_old > val->intval)
|
|
val->intval = fuelgauge->capacity_old - 1;
|
|
}
|
|
|
|
/* keep SOC stable in abnormal status */
|
|
if (fuelgauge->pdata->capacity_calculation_type &
|
|
SEC_FUELGAUGE_CAPACITY_TYPE_SKIP_ABNORMAL) {
|
|
if (!fuelgauge->is_charging &&
|
|
fuelgauge->capacity_old < val->intval) {
|
|
dev_err(&fuelgauge->client->dev,
|
|
"%s: capacity (old %d : new %d)\n",
|
|
__func__, fuelgauge->capacity_old, val->intval);
|
|
val->intval = fuelgauge->capacity_old;
|
|
}
|
|
}
|
|
|
|
/* updated old capacity */
|
|
fuelgauge->capacity_old = val->intval;
|
|
}
|
|
|
|
static int sec_fg_get_property(struct power_supply *psy,
|
|
enum power_supply_property psp,
|
|
union power_supply_propval *val)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge =
|
|
container_of(psy, struct sec_fuelgauge_info, psy_fg);
|
|
int soc_type = val->intval;
|
|
|
|
switch (psp) {
|
|
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
|
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
|
|
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
|
case POWER_SUPPLY_PROP_CURRENT_AVG:
|
|
case POWER_SUPPLY_PROP_ENERGY_NOW:
|
|
case POWER_SUPPLY_PROP_CAPACITY:
|
|
case POWER_SUPPLY_PROP_TEMP:
|
|
case POWER_SUPPLY_PROP_TEMP_AMBIENT:
|
|
if (!sec_hal_fg_get_property(fuelgauge->client, psp, val))
|
|
return -EINVAL;
|
|
if (psp == POWER_SUPPLY_PROP_CAPACITY) {
|
|
if (soc_type == SEC_FUELGAUGE_CAPACITY_TYPE_RAW)
|
|
break;
|
|
|
|
if (fuelgauge->pdata->capacity_calculation_type &
|
|
(SEC_FUELGAUGE_CAPACITY_TYPE_SCALE |
|
|
SEC_FUELGAUGE_CAPACITY_TYPE_DYNAMIC_SCALE))
|
|
sec_fg_get_scaled_capacity(fuelgauge, val);
|
|
|
|
/* capacity should be between 0% and 100%
|
|
* (0.1% degree)
|
|
*/
|
|
if (val->intval > 1000)
|
|
val->intval = 1000;
|
|
if (val->intval < 0)
|
|
val->intval = 0;
|
|
|
|
/* get only integer part */
|
|
val->intval /= 10;
|
|
|
|
/* check whether doing the wake_unlock */
|
|
if ((val->intval > fuelgauge->pdata->fuel_alert_soc) &&
|
|
fuelgauge->is_fuel_alerted) {
|
|
wake_unlock(&fuelgauge->fuel_alert_wake_lock);
|
|
sec_hal_fg_fuelalert_init(fuelgauge->client,
|
|
fuelgauge->pdata->fuel_alert_soc);
|
|
}
|
|
|
|
/* (Only for atomic capacity)
|
|
* In initial time, capacity_old is 0.
|
|
* and in resume from sleep,
|
|
* capacity_old is too different from actual soc.
|
|
* should update capacity_old
|
|
* by val->intval in booting or resume.
|
|
*/
|
|
if (fuelgauge->initial_update_of_soc) {
|
|
/* updated old capacity */
|
|
fuelgauge->capacity_old = val->intval;
|
|
fuelgauge->initial_update_of_soc = false;
|
|
break;
|
|
}
|
|
|
|
if (fuelgauge->pdata->capacity_calculation_type &
|
|
(SEC_FUELGAUGE_CAPACITY_TYPE_ATOMIC |
|
|
SEC_FUELGAUGE_CAPACITY_TYPE_SKIP_ABNORMAL))
|
|
sec_fg_get_atomic_capacity(fuelgauge, val);
|
|
}
|
|
break;
|
|
case POWER_SUPPLY_PROP_STATUS:
|
|
case POWER_SUPPLY_PROP_CHARGE_FULL:
|
|
return -ENODATA;
|
|
default:
|
|
return -EINVAL;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static int sec_fg_calculate_dynamic_scale(
|
|
struct sec_fuelgauge_info *fuelgauge)
|
|
{
|
|
union power_supply_propval raw_soc_val;
|
|
|
|
raw_soc_val.intval = SEC_FUELGAUGE_CAPACITY_TYPE_RAW;
|
|
if (!sec_hal_fg_get_property(fuelgauge->client,
|
|
POWER_SUPPLY_PROP_CAPACITY,
|
|
&raw_soc_val))
|
|
return -EINVAL;
|
|
raw_soc_val.intval /= 10;
|
|
|
|
if (raw_soc_val.intval <
|
|
fuelgauge->pdata->capacity_max -
|
|
fuelgauge->pdata->capacity_max_margin) {
|
|
fuelgauge->capacity_max =
|
|
fuelgauge->pdata->capacity_max -
|
|
fuelgauge->pdata->capacity_max_margin;
|
|
dev_dbg(&fuelgauge->client->dev, "%s: capacity_max (%d)",
|
|
__func__, fuelgauge->capacity_max);
|
|
} else {
|
|
fuelgauge->capacity_max =
|
|
(raw_soc_val.intval >
|
|
fuelgauge->pdata->capacity_max +
|
|
fuelgauge->pdata->capacity_max_margin) ?
|
|
(fuelgauge->pdata->capacity_max +
|
|
fuelgauge->pdata->capacity_max_margin) :
|
|
raw_soc_val.intval;
|
|
dev_dbg(&fuelgauge->client->dev, "%s: raw soc (%d)",
|
|
__func__, fuelgauge->capacity_max);
|
|
}
|
|
|
|
fuelgauge->capacity_max =
|
|
(fuelgauge->capacity_max * 99 / 100);
|
|
|
|
/* update capacity_old for sec_fg_get_atomic_capacity algorithm */
|
|
fuelgauge->capacity_old = 100;
|
|
|
|
dev_info(&fuelgauge->client->dev, "%s: %d is used for capacity_max\n",
|
|
__func__, fuelgauge->capacity_max);
|
|
|
|
return fuelgauge->capacity_max;
|
|
}
|
|
|
|
static int sec_fg_set_property(struct power_supply *psy,
|
|
enum power_supply_property psp,
|
|
const union power_supply_propval *val)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge =
|
|
container_of(psy, struct sec_fuelgauge_info, psy_fg);
|
|
|
|
switch (psp) {
|
|
case POWER_SUPPLY_PROP_STATUS:
|
|
if (val->intval == POWER_SUPPLY_STATUS_FULL)
|
|
sec_hal_fg_full_charged(fuelgauge->client);
|
|
break;
|
|
case POWER_SUPPLY_PROP_CHARGE_FULL:
|
|
if (val->intval == POWER_SUPPLY_TYPE_BATTERY) {
|
|
if (fuelgauge->pdata->capacity_calculation_type &
|
|
SEC_FUELGAUGE_CAPACITY_TYPE_DYNAMIC_SCALE)
|
|
sec_fg_calculate_dynamic_scale(fuelgauge);
|
|
}
|
|
break;
|
|
case POWER_SUPPLY_PROP_ONLINE:
|
|
fuelgauge->cable_type = val->intval;
|
|
if (val->intval == POWER_SUPPLY_TYPE_BATTERY)
|
|
fuelgauge->is_charging = false;
|
|
else
|
|
fuelgauge->is_charging = true;
|
|
case POWER_SUPPLY_PROP_CAPACITY:
|
|
if (val->intval == SEC_FUELGAUGE_CAPACITY_TYPE_RESET) {
|
|
fuelgauge->initial_update_of_soc = true;
|
|
if (!sec_hal_fg_reset(fuelgauge->client))
|
|
return -EINVAL;
|
|
else
|
|
break;
|
|
}
|
|
case POWER_SUPPLY_PROP_TEMP:
|
|
case POWER_SUPPLY_PROP_TEMP_AMBIENT:
|
|
if (!sec_hal_fg_set_property(fuelgauge->client, psp, val))
|
|
return -EINVAL;
|
|
break;
|
|
default:
|
|
return -EINVAL;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static void sec_fg_isr_work(struct work_struct *work)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge =
|
|
container_of(work, struct sec_fuelgauge_info, isr_work.work);
|
|
|
|
/* process for fuel gauge chip */
|
|
sec_hal_fg_fuelalert_process(fuelgauge, fuelgauge->is_fuel_alerted);
|
|
|
|
/* process for others */
|
|
if (fuelgauge->pdata->fuelalert_process != NULL)
|
|
fuelgauge->pdata->fuelalert_process(fuelgauge->is_fuel_alerted);
|
|
}
|
|
|
|
static irqreturn_t sec_fg_irq_thread(int irq, void *irq_data)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge = irq_data;
|
|
bool fuel_alerted;
|
|
|
|
if (fuelgauge->pdata->fuel_alert_soc >= 0) {
|
|
fuel_alerted =
|
|
sec_hal_fg_is_fuelalerted(fuelgauge->client);
|
|
|
|
dev_info(&fuelgauge->client->dev,
|
|
"%s: Fuel-alert %salerted!\n",
|
|
__func__, fuel_alerted ? "" : "NOT ");
|
|
|
|
if (fuel_alerted == fuelgauge->is_fuel_alerted) {
|
|
if (!fuelgauge->pdata->repeated_fuelalert) {
|
|
dev_dbg(&fuelgauge->client->dev,
|
|
"%s: Fuel-alert Repeated (%d)\n",
|
|
__func__, fuelgauge->is_fuel_alerted);
|
|
return IRQ_HANDLED;
|
|
}
|
|
}
|
|
|
|
if (fuel_alerted)
|
|
wake_lock(&fuelgauge->fuel_alert_wake_lock);
|
|
else
|
|
wake_unlock(&fuelgauge->fuel_alert_wake_lock);
|
|
|
|
schedule_delayed_work(&fuelgauge->isr_work, 0);
|
|
|
|
fuelgauge->is_fuel_alerted = fuel_alerted;
|
|
}
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
static int sec_fg_create_attrs(struct device *dev)
|
|
{
|
|
int i, rc;
|
|
|
|
for (i = 0; i < ARRAY_SIZE(sec_fg_attrs); i++) {
|
|
rc = device_create_file(dev, &sec_fg_attrs[i]);
|
|
if (rc)
|
|
goto create_attrs_failed;
|
|
}
|
|
goto create_attrs_succeed;
|
|
|
|
create_attrs_failed:
|
|
dev_err(dev, "%s: failed (%d)\n", __func__, rc);
|
|
while (i--)
|
|
device_remove_file(dev, &sec_fg_attrs[i]);
|
|
create_attrs_succeed:
|
|
return rc;
|
|
}
|
|
|
|
ssize_t sec_fg_show_attrs(struct device *dev,
|
|
struct device_attribute *attr, char *buf)
|
|
{
|
|
const ptrdiff_t offset = attr - sec_fg_attrs;
|
|
int i = 0;
|
|
|
|
switch (offset) {
|
|
case FG_REG:
|
|
case FG_DATA:
|
|
case FG_REGS:
|
|
i = sec_hal_fg_show_attrs(dev, offset, buf);
|
|
break;
|
|
default:
|
|
i = -EINVAL;
|
|
break;
|
|
}
|
|
|
|
return i;
|
|
}
|
|
|
|
ssize_t sec_fg_store_attrs(struct device *dev,
|
|
struct device_attribute *attr,
|
|
const char *buf, size_t count)
|
|
{
|
|
const ptrdiff_t offset = attr - sec_fg_attrs;
|
|
int ret = 0;
|
|
|
|
switch (offset) {
|
|
case FG_REG:
|
|
case FG_DATA:
|
|
ret = sec_hal_fg_store_attrs(dev, offset, buf, count);
|
|
break;
|
|
default:
|
|
ret = -EINVAL;
|
|
break;
|
|
}
|
|
|
|
return ret;
|
|
}
|
|
|
|
#ifdef CONFIG_OF
|
|
static int fuelgauge_parse_dt(struct device *dev,
|
|
struct sec_fuelgauge_info *fuelgauge)
|
|
{
|
|
struct device_node *np = dev->of_node;
|
|
sec_battery_platform_data_t *pdata = fuelgauge->pdata;
|
|
int ret;
|
|
#if 0
|
|
int ta_int_gpio;
|
|
sec_battery_platform_data_t sec_battery_pdata;
|
|
#endif
|
|
|
|
/* reset, irq gpio info */
|
|
if (np == NULL) {
|
|
pr_err("%s np NULL\n", __func__);
|
|
} else {
|
|
pdata->fg_irq = of_get_named_gpio(np, "fuelgauge,fuel_int", 0);
|
|
if (pdata->fg_irq < 0) {
|
|
pr_err("%s error reading fg_irq = %d\n", __func__, pdata->fg_irq);
|
|
pdata->fg_irq = 0;
|
|
}
|
|
|
|
ret = of_property_read_u32(np, "fuelgauge,capacity_max",
|
|
&pdata->capacity_max);
|
|
if (ret < 0)
|
|
pr_err("%s error reading capacity_max %d\n", __func__, ret);
|
|
|
|
ret = of_property_read_u32(np, "fuelgauge,capacity_max_margin",
|
|
&pdata->capacity_max_margin);
|
|
if (ret < 0)
|
|
pr_err("%s error reading capacity_max_margin %d\n", __func__, ret);
|
|
|
|
ret = of_property_read_u32(np, "fuelgauge,capacity_min",
|
|
&pdata->capacity_min);
|
|
if (ret < 0)
|
|
pr_err("%s error reading capacity_min %d\n", __func__, ret);
|
|
|
|
ret = of_property_read_u32(np, "fuelgauge,capacity_calculation_type",
|
|
&pdata->capacity_calculation_type);
|
|
if (ret < 0)
|
|
pr_err("%s error reading capacity_calculation_type %d\n",
|
|
__func__, ret);
|
|
ret = of_property_read_u32(np, "fuelgauge,fuel_alert_soc",
|
|
&pdata->fuel_alert_soc);
|
|
if (ret < 0)
|
|
pr_err("%s error reading pdata->fuel_alert_soc %d\n",
|
|
__func__, ret);
|
|
pdata->repeated_fuelalert = of_property_read_bool(np,
|
|
"fuelgaguge,repeated_fuelalert");
|
|
|
|
pr_info("%s fg_irq: %d, capacity_max: %d\n"
|
|
"cpacity_max_margin: %d, capacity_min: %d\n"
|
|
"calculation_type: 0x%x, fuel_alert_soc: %d,\n"
|
|
"repeated_fuelalert: %d\n",
|
|
__func__, pdata->fg_irq,
|
|
pdata->capacity_max, pdata->capacity_max_margin,
|
|
pdata->capacity_min, pdata->capacity_calculation_type,
|
|
pdata->fuel_alert_soc, pdata->repeated_fuelalert);
|
|
}
|
|
return 0;
|
|
}
|
|
#endif
|
|
|
|
static int __devinit sec_fuelgauge_probe(struct i2c_client *client,
|
|
const struct i2c_device_id *id)
|
|
{
|
|
struct i2c_adapter *adapter = to_i2c_adapter(client->dev.parent);
|
|
struct sec_fuelgauge_info *fuelgauge;
|
|
sec_battery_platform_data_t *pdata = NULL;
|
|
struct battery_data_t *battery_data = NULL;
|
|
int ret = 0;
|
|
union power_supply_propval raw_soc_val;
|
|
|
|
dev_info(&client->dev,
|
|
"%s: SEC Fuelgauge Driver Loading\n", __func__);
|
|
|
|
if (!i2c_check_functionality(adapter, I2C_FUNC_SMBUS_BYTE))
|
|
return -EIO;
|
|
|
|
fuelgauge = kzalloc(sizeof(*fuelgauge), GFP_KERNEL);
|
|
if (!fuelgauge)
|
|
return -ENOMEM;
|
|
|
|
mutex_init(&fuelgauge->fg_lock);
|
|
|
|
fuelgauge->client = client;
|
|
|
|
if (client->dev.of_node) {
|
|
int error;
|
|
pdata = devm_kzalloc(&client->dev,
|
|
sizeof(sec_battery_platform_data_t),
|
|
GFP_KERNEL);
|
|
if (!pdata) {
|
|
dev_err(&client->dev, "Failed to allocate memory\n");
|
|
ret = -ENOMEM;
|
|
goto err_free;
|
|
}
|
|
battery_data = devm_kzalloc(&client->dev,
|
|
sizeof(struct battery_data_t),
|
|
GFP_KERNEL);
|
|
if (!battery_data) {
|
|
dev_err(&client->dev, "Failed to allocate memory\n");
|
|
devm_kfree(&client->dev, pdata);
|
|
ret = -ENOMEM;
|
|
goto err_free;
|
|
}
|
|
pdata->battery_data = (void *)battery_data;
|
|
fuelgauge->pdata = pdata;
|
|
error = fuelgauge_parse_dt(&client->dev, fuelgauge);
|
|
if (error) {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to get fuel_int\n", __func__);
|
|
}
|
|
} else {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to get of_node\n", __func__);
|
|
fuelgauge->pdata = client->dev.platform_data;
|
|
}
|
|
|
|
i2c_set_clientdata(client, fuelgauge);
|
|
|
|
if (!sec_hal_fg_init(fuelgauge->client)) {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to Initialize Fuelgauge\n", __func__);
|
|
goto err_free;
|
|
}
|
|
|
|
fuelgauge->psy_fg.name = "sec-fuelgauge";
|
|
fuelgauge->psy_fg.type = POWER_SUPPLY_TYPE_UNKNOWN;
|
|
fuelgauge->psy_fg.get_property = sec_fg_get_property;
|
|
fuelgauge->psy_fg.set_property = sec_fg_set_property;
|
|
fuelgauge->psy_fg.properties = sec_fuelgauge_props;
|
|
fuelgauge->psy_fg.num_properties =
|
|
ARRAY_SIZE(sec_fuelgauge_props);
|
|
fuelgauge->capacity_max = fuelgauge->pdata->capacity_max;
|
|
raw_soc_val.intval = SEC_FUELGAUGE_CAPACITY_TYPE_RAW;
|
|
sec_hal_fg_get_property(fuelgauge->client,
|
|
POWER_SUPPLY_PROP_CAPACITY, &raw_soc_val);
|
|
raw_soc_val.intval /= 10;
|
|
if(raw_soc_val.intval > fuelgauge->pdata->capacity_max)
|
|
sec_fg_calculate_dynamic_scale(fuelgauge);
|
|
/*
|
|
if (!fuelgauge->pdata->fg_gpio_init()) {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to Initialize GPIO\n", __func__);
|
|
goto err_free;
|
|
}
|
|
*/
|
|
ret = power_supply_register(&client->dev, &fuelgauge->psy_fg);
|
|
if (ret) {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to Register psy_fg\n", __func__);
|
|
goto err_free;
|
|
}
|
|
|
|
if (fuelgauge->pdata->fg_irq) {
|
|
fuelgauge->fg_irq = gpio_to_irq(fuelgauge->pdata->fg_irq);
|
|
INIT_DELAYED_WORK(
|
|
&fuelgauge->isr_work, sec_fg_isr_work);
|
|
|
|
ret = request_threaded_irq(fuelgauge->fg_irq,
|
|
NULL, sec_fg_irq_thread,
|
|
IRQF_TRIGGER_FALLING | IRQF_TRIGGER_RISING | IRQF_ONESHOT,
|
|
"fuelgauge-irq", fuelgauge);
|
|
if (ret) {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to Reqeust IRQ\n", __func__);
|
|
goto err_supply_unreg;
|
|
}
|
|
|
|
ret = enable_irq_wake(fuelgauge->fg_irq);
|
|
if (ret < 0)
|
|
dev_err(&client->dev,
|
|
"%s: Failed to Enable Wakeup Source(%d)\n",
|
|
__func__, ret);
|
|
}
|
|
|
|
fuelgauge->is_fuel_alerted = false;
|
|
if (fuelgauge->pdata->fuel_alert_soc >= 0) {
|
|
if (sec_hal_fg_fuelalert_init(fuelgauge->client,
|
|
fuelgauge->pdata->fuel_alert_soc))
|
|
wake_lock_init(&fuelgauge->fuel_alert_wake_lock,
|
|
WAKE_LOCK_SUSPEND, "fuel_alerted");
|
|
else {
|
|
dev_err(&client->dev,
|
|
"%s: Failed to Initialize Fuel-alert\n",
|
|
__func__);
|
|
goto err_irq;
|
|
}
|
|
}
|
|
|
|
fuelgauge->initial_update_of_soc = true;
|
|
|
|
ret = sec_fg_create_attrs(fuelgauge->psy_fg.dev);
|
|
if (ret) {
|
|
dev_err(&client->dev,
|
|
"%s : Failed to create_attrs\n", __func__);
|
|
goto err_irq;
|
|
}
|
|
|
|
dev_info(&client->dev,
|
|
"%s: SEC Fuelgauge Driver Loaded\n", __func__);
|
|
return 0;
|
|
|
|
err_irq:
|
|
if (fuelgauge->fg_irq)
|
|
free_irq(fuelgauge->fg_irq, fuelgauge);
|
|
wake_lock_destroy(&fuelgauge->fuel_alert_wake_lock);
|
|
err_supply_unreg:
|
|
power_supply_unregister(&fuelgauge->psy_fg);
|
|
err_free:
|
|
mutex_destroy(&fuelgauge->fg_lock);
|
|
kfree(fuelgauge);
|
|
|
|
return ret;
|
|
}
|
|
|
|
static int __devexit sec_fuelgauge_remove(
|
|
struct i2c_client *client)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge = i2c_get_clientdata(client);
|
|
|
|
if (fuelgauge->pdata->fuel_alert_soc >= 0)
|
|
wake_lock_destroy(&fuelgauge->fuel_alert_wake_lock);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int sec_fuelgauge_suspend(struct device *dev)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge = dev_get_drvdata(dev);
|
|
|
|
if (!sec_hal_fg_suspend(fuelgauge->client))
|
|
dev_err(&fuelgauge->client->dev,
|
|
"%s: Failed to Suspend Fuelgauge\n", __func__);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int sec_fuelgauge_resume(struct device *dev)
|
|
{
|
|
struct sec_fuelgauge_info *fuelgauge = dev_get_drvdata(dev);
|
|
|
|
if (!sec_hal_fg_resume(fuelgauge->client))
|
|
dev_err(&fuelgauge->client->dev,
|
|
"%s: Failed to Resume Fuelgauge\n", __func__);
|
|
|
|
fuelgauge->initial_update_of_soc = true;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void sec_fuelgauge_shutdown(struct i2c_client *client)
|
|
{
|
|
}
|
|
|
|
static const struct i2c_device_id sec_fuelgauge_id[] = {
|
|
{"sec-fuelgauge", 0},
|
|
{}
|
|
};
|
|
|
|
static const struct dev_pm_ops sec_fuelgauge_pm_ops = {
|
|
.suspend = sec_fuelgauge_suspend,
|
|
.resume = sec_fuelgauge_resume,
|
|
};
|
|
|
|
MODULE_DEVICE_TABLE(i2c, sec_fuelgauge_id);
|
|
|
|
#if defined(CONFIG_OF)
|
|
static struct of_device_id sec_fuelgauge_i2c_dt_ids[] = {
|
|
{ .compatible = "sec-fuelgauge,i2c" },
|
|
{ }
|
|
};
|
|
MODULE_DEVICE_TABLE(of, sec_fuelgauge_i2c_dt_ids);
|
|
#endif /* CONFIG_OF */
|
|
|
|
static struct i2c_driver sec_fuelgauge_driver = {
|
|
.driver = {
|
|
.name = "sec-fuelgauge",
|
|
.owner = THIS_MODULE,
|
|
#ifdef CONFIG_PM
|
|
.pm = &sec_fuelgauge_pm_ops,
|
|
#endif
|
|
#if defined(CONFIG_OF)
|
|
.of_match_table = sec_fuelgauge_i2c_dt_ids,
|
|
#endif /* CONFIG_OF */
|
|
},
|
|
.probe = sec_fuelgauge_probe,
|
|
.remove = __devexit_p(sec_fuelgauge_remove),
|
|
.shutdown = sec_fuelgauge_shutdown,
|
|
.id_table = sec_fuelgauge_id,
|
|
};
|
|
|
|
static int __init sec_fuelgauge_init(void)
|
|
{
|
|
dev_info(0, "%s: \n", __func__);
|
|
return i2c_add_driver(&sec_fuelgauge_driver);
|
|
}
|
|
|
|
static void __exit sec_fuelgauge_exit(void)
|
|
{
|
|
i2c_del_driver(&sec_fuelgauge_driver);
|
|
}
|
|
|
|
module_init(sec_fuelgauge_init);
|
|
module_exit(sec_fuelgauge_exit);
|
|
|
|
MODULE_DESCRIPTION("Samsung Fuel Gauge Driver");
|
|
MODULE_AUTHOR("Samsung Electronics");
|
|
MODULE_LICENSE("GPL");
|